Easy cooling row cw.
Apc inrow cooling capacity.
The big one is rd 600mm with capacity 25kw 29kw can be archived in special condition.
This design prevents hot air recirculation while improving cooling predictability and allowing for a pay as you grow environment.
The inrow rc is a chilled.
2020 apc by schneider electric.
Row based architecture captures hot exhaust air directly from the it equipment thereby increasing the unit s sensible cooling capacity over traditional cooling architectures.
Uniflair direct expansion inrow cooling features benefits.
The apc infrastruxure inrow rc is a computer room air conditioning system designed for installation in the row to maximize sensible cooling and increase efficiency.
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures.
The unit captures heat directly from the hot aisle and distributes cool air ensuring that equipment temperatures are constantly held to setpoint conditions.
Uniflair inrow cooling accessories.
The inrow direct expansion family closely couples the cooling with the heat source improving predictability and efficiency.
Uniflair inrow cooling accessories.
Status in the event of a power failure.
Ensures server exhaust air is returned to the inrow cooling units for maximum cooling predictability.
Intelligent controls actively adjust to match the load addressing the dynamic demands of today s it environments.
Provides remote notification of failures when used with apc environmental.
This unit need to buy condenser units.
If you want the use the inrow rd there are 02 version inrow rd.
It operators looking to improve efficiency or deploy higher density equipment will benefit from the modular design of the uniflair chilled water inrow products.
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures.
The solution is an excellent choice for medium to large data centers.
Apc by schneider electric inrow chilled water cooling close coupled chilled water cooling for medium to large data centers is the predictable solution for an unpredictable environment.
Closely couples the cooling with the it heat load.
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures.
Uniflair direct expansion inrow cooling.
Thank you for subscribing to.
Through the microprocessor controller visibility into the operation and health of the unit is provided.
The small one is rd 300mm with capacity 7kw 9kw can be archived in some condition.
Through the microprocessor controller visibility into the operation and health of the unit is provided.